Medical Waste Incinerator Manufacturers: HICLOVER Leading the Industry Medical waste disposal is a crucial aspect of […]
medical waste diesel burner Burning Price:47.5–– 50kg/hour. Minimum Operating Temperature:850 o C( key combustion). Optimum Operating […]
Skid-Mounted Incinerator: The Ultimate Portable Waste Management Solution In today’s fast-paced industrial and environmental landscape, efficient […]
Municipal solid waste (MSW) management is a critical challenge for cities and communities worldwide. With urbanization accelerating and waste volumes soaring, municipalities need **reliable incinerators** that combine efficiency, environmental compliance, and durability. HICLOVER, a leading incinerator manufacturer, offers cutting-edge solutions designed to address these challenges. From containerized mobile units to high-capacity systems, our incinerators ensure safe, efficient, and eco-friendly waste disposal. Explore how HICLOVER’s technology supports sustainable municipal waste management while meeting global standards.   — ### **The Growing Challenge of Municipal Solid Waste**   Rapid population growth and industrial activity generate enormous volumes of municipal solid waste, including household refuse, commercial debris, and non-recyclable materials. Traditional landfills are unsustainable due to space constraints, groundwater contamination risks, and greenhouse gas emissions. Incineration has emerged as a viable alternative, reducing waste volume by up to 90% while generating energy. However, not all incinerators are created equal. Municipalities require **reliable incinerators for municipal solid waste management** that prioritize:   – **High burning efficiency** (5–1,000 kg/hour capacity)   – **Emission control** (wet/dry scrubbers, multi-chamber designs)   – **Fuel flexibility** (diesel, natural gas, LPG)   – **Mobility and scalability** (containerized, trailer-mounted options)   — ### **HICLOVER’s Advanced Incineration Technology**   As a trusted name in waste management, HICLOVER delivers **municipal waste incineration solutions** tailored to diverse needs. Our systems integrate innovative engineering with user-friendly operation, making them ideal for urban centers, remote regions, and crisis zones.   #### **1. Robust Product Range for Every Need**   HICLOVER’s incinerators cater to small towns and megacities alike:   – **Containerized Mobile Incinerators**: Pre-installed in ISO containers for rapid deployment. No construction required—ideal for disaster relief or temporary sites.   – **Top-Loading Incinerators**: Efficiently handle bulk waste with capacities up to 1,000 kg/hour.   – **Automatic Incinerators**: PLC-controlled systems minimize manual intervention, ensuring consistent performance.   […]
CPASA (Community Partners Against Substance Abuse) Director Dawn Conerton was thrilled to announce the new purchase. […]
Heathrow Airport has announced plans to move an incinerator away from Stanwell and create a 15 […]
We have a 70 bed medical facility in namibia. There is a potential of getting customers […]
Understanding Pet Cremation Ash Processing After the cremation of a pet, the remaining bone fragments are […]
Key Features: — — Full array burner with Saved money Tiny Scale incinerator, Criterion Small-Large Scale […]
Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator […]
Basic Info. Model NO.:animal cremation equipments china Export Markets:Global Product Description Nanjing Clover Medical Technology Co., […]
BIOHAZARD DISPOSAL: CONTAINER GENERAL INCINERATOR, IDEAL FOR INCINERATION OF VARIOUS TYPES OF WASTE, TOTALLY CONTAINERISED IN […]
Class 2          Industrial Incinerators Class 2A:    Commercial Incinerators for the disposal of waste that contains […]
*** Primary combustion chamber & secondary combustion chamber *** Smoke filter chamber(dry scrubber) *** stainless steel […]
hot medical waste disposing machine, Operation Condition: 8-16 hr/ day Control: Built-in data recordingOperating temperature: Incinerator /Primary Combustion ChamberPrimary Chamber: 900 – 1200 0C Type: continuous loading, Top LoadingCapacity/Burn rate per hour: 250 -300 kg/hr Material:External- 3 layers Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shockSecondary Combustion Chamber:Type: horizontal/verticalTemperature:  1200- 1300 oCResidence time of gases : >2 secondsAsh Residue: <5% of original waste sizeAsh Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ashFlue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacityAuxiliary device: Water level gauge, pressure sensor, PH sensor..etc Auxiliary device: Fuel cut-off deviceWaste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                      Chimney (Stack):Type: Vertical typeheight:>7 meter’Material: Fireproof cast, stainless steelOUTPUT: GAS- SMOKELESS,ODORLESS ASH -Max <5% of original waste sizeReduction of Pollutant gas SO2, HCL, HF and line particulateEmission standard:WHO/ EuropeanTest report for emission testing provided?Heat exchange mode: Automatic Accessories:  All standard accessories for incinerator, including but not limited to loading system, heat exchangers, pollution control system, ash removal system, including ladder and oil tanker (2500litre capacity).Operating Environment: The incinerator is capable to operate at the altitude of 2400mt above sea level. (according to the site conditions)Power Requirement:220 Vac single phase or 380 Vac three phase 4 wire system  50HZ   Installation Testing and Commissioning :   to be conducted by certified or qualified personnel.  Supplier shall provide the following documentation    User (Operating) manual in English. Service (Technical / Maintenance) manual in English. Certificate of calibration and inspection from factory. Fast moving spare parts: Supplier is able to provide fast moving spare parts with quantities as described in the price schedule or their equivalent. Training: Supplier is able to provide training on operation, management and maintenance of incinerators.   Warranty Comprehensive warranty for minimum 2 year. Maintenance Service during Warranty Period During warranty period supplier must ensure, corrective/breakdown maintenance whenever required. Supplier has a local agent or branch office in Ethiopia (please indicate the name and contact details of the agent) Supplier provides labor, lifting equipment and tools needed for the installation, testing and commissioning of the incinerator. The supplier will be responsible for the safety of its staff, workers and laborers during the installation, testing & commisssioning Able to provides all necessary information that would be used as an input for preparation of floor (platform) and room for the incinerator to be supplied such as the following; Lay outs (drawings) and  pictures of the incinerators to be installed  Length, width and height of incinerator, Area (length x width) for the floor (platform) and Length, width and height for roofing, for each type of incinerators to be installed Needs during the transport, installation, assembly, commissioning and operation of the equipment in terms of access points, available space to operate (inside and outside of the room), ways to get to the site where the equipment will be placed or any others. ; Technical Specifications (fuel consumption rate, weight, anchoring system, support points, etc.); Chimney specifications to be used for the roof design ( size, support needs, insulation); Considerations related to operation and Maintenance, for e.g., minimum available area to perform routine maintenance tasks and replacement of key parts that need to be changed more frequently; Any consideration/need of the incinerator while being operated that might impact the design of the room/shelter where it will be placed.Other important information to be considered that can influence or impact the designing and building processes of the infrastructure for the incinerators, for example area dimension for other accessary parts like fuel tanker storage, if applicable, etc…. Delivery time (DAP, Addis Ababa) in weeksName of manufacturer including website of the manufacturer &/ supplier & country of origin
About

HICLOVER Solution for Fighting COVID-19, with ISO9001:2015/CE(2006/42/EC,2014/30/EU) Certification.Medical Waste Incinerator |Mobile Incinerator|
Pet Animal Incinerator|Municipal Solid Waste Incinerator