Compact Top-Loading Medical Waste Incinerator (10C20 kg/hour)

The HICLOVER Compact Top-Loading Medical Waste Incinerator is a purpose-built solution for healthcare institutions that require safe, compliant, and cost-effective treatment of infectious and general medical waste. With a processing capacity of 10C20 kg/hour, this model is specifically optimized for small clinics, rural health posts, mobile medical stations, humanitarian missions, and low-infrastructure environments.

Designed for rapid deployment and minimal site preparation, this system offers excellent performance at a low operational cost, making it ideal for donor-funded programs, emergency procurement, and decentralized healthcare facilities.


1. Purpose & Application

This compact unit is engineered to meet the increasing demand for on-site medical waste destruction in locations where centralized treatment is unavailable or unreliable. It provides:

  • Safe disposal of infectious, contaminated, and general medical waste

  • Reliable operation in rural, remote, or temporary healthcare settings

  • Fast installation―ideal for emergency response, outbreak control, and mobile missions

Typical users include Ministries of Health, UN agencies, NGOs, private hospitals, veterinary stations, laboratory networks, and field hospitals.


2. Key Marketing Advantages for Procurement Evaluators

Compact, Small-Capacity Design

The system occupies very little space, allowing installation in constrained facilities, rooftops, modular clinics, or containerized rooms.

Rapid Deployment

All components are pre-assembled, enabling commissioning within hours. No complex civil works are required.

Budget-Friendly Operation

Low fuel consumption and simple routine maintenance translate to lower lifetime operational costs―ideal for limited budgets and donor-supported health programs.

Top-Loading for Safe and Easy Operation

The top open door allows staff to load waste directly from above, significantly reducing manual handling risks. Perfect for low-resource environments with limited technical staff.

Dual-Chamber Clean-Burning Design

Two high-temperature chambers ensure full destruction of pathogens, sharps, PPE, laboratory residues, and general medical waste.

Reliable Emission Management

Standard dry filtration neutralizes acidic and alkaline components. Optional wet scrubber enhances compliance where stricter air-quality standards are required.


3. Technical Overview (Procurement-Focused)

Combustion Chambers

Fuel & Burners

  • Standard fuel: Diesel

  • Optional: Natural Gas / LPG

  • Burners:

    • Primary: G10LC single-stage, ~4 kg/hr

    • Secondary: G10LC single-stage, ~4 kg/hr

  • Maximum theoretical consumption: 8 kg/hr, actual use lower due to intermittent firing and waste self-combustion

Flue Gas Treatment

  • Dry scrubber (standard): Chemical neutralization of acidic gases

  • Wet scrubber (optional): For enhanced particulate and gas removal

Control System

  • PLC automatic control with temperature monitoring

  • Safe and intuitive operation suitable for non-technical personnel


4. Reasons This Model Scores Highly in Tender Evaluations

  • Meets essential WHO-style medical waste treatment principles

  • Compact design minimizes space and installation barriers

  • Low operational cost, ideal for constrained budgets

  • High-temperature destruction (up to 1000C1200°C)

  • Dual combustion ensures cleaner emissions

  • Suitable for on-grid and off-grid locations

  • Proven performance in international deployments

  • Supports procurement goals for sustainability, safety, and compliance

This model is particularly successful in settings such as rural clinics in Africa, mobile vaccination centers in Southeast Asia, emergency medical posts in the Middle East, and remote laboratory networks in Latin America.


5. Value Proposition for Donors & Funding Agencies

The HICLOVER compact incinerator delivers a strong balance of technical reliability, cost efficiency, and rapid field readiness, making it an attractive investment for:

  • Government health programs

  • UN emergency operations

  • International development banks

  • NGO-led health projects

  • Humanitarian and disaster response programs

Its small-capacity design ensures affordable lifecycle costs, simple maintenance, and consistent operational performance―even in low-resource settings.


Conclusion

The HICLOVER Top-Loading Incinerator (10C20 kg/h) offers a powerful combination of compact structure, rapid deployment, low fuel usage, and strong compliance features. It is specifically designed to help healthcare facilities―large or small―manage infectious waste safely and independently of external disposal systems.

This solution supports public health protection, infection prevention and control, and sustainable waste-management practices, making it an excellent choice for competitive tenders and institutional procurement.

Mobile: +86-13813931455(WhatsApp)

Email:     [email protected]     
Email:     [email protected] 

 

2025-11-24/13:51:25

Incinerator Items/Model

HICLOVER TS100(PLC)

 

Burn Rate (Average)

100kg/hour

Feed Capacity(Average)

150kg/feeding

Control Mode

PLC Automatic

Intelligent Sensor

Continuously Feeding with Worker Protection

High Temperature Retention(HTR)

Yes (Adjustable)

Intelligent Save Fuel Function

Yes

Primary Combustion Chamber

1200Liters(1.2m3)

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Burner Type

Italy Brand

Temperature Monitor

Yes

Temperature Thermometer

Corundum Probe Tube, 1400℃Rate.

Temperature Protection

Yes

Automatic Cooling

Yes

Automatic False Alarm

Yes

Automatic Protection Operator(APO)

Yes

Time Setting

Yes

Progress Display Bar

3.7 in” LCD Screen

Oil Tank

200L

Chimney Type

 Stainless Steel 304

1st. Chamber Temperature

800℃–1000℃

2nd. Chamber Temperature

1000℃-1300℃

Residency Time

2.0 Sec.

Gross Weight

7000kg

External Dimensions

270x170x190cm(Incinerator Main Body)

Burner operation

Automatic On/Off

Dry Scrubber

Optional

Wet Scrubber

Optional

Top Loading Door

Optional

Asbestos Mercury Material

None

Heat Heart Technology(HHT)

Optional

Dual Fuel Type(Oil&Gas)

Optional

Dual Control Mode(Manual/Automatic)

Optional

Temperature Record

Optional

Enhanced Temperature Thermometer

Optional

Incinerator Operator PPE Kits

Optional

Backup Spare Parts Kits

Optional

Mobile Type

Optional:Containerized/Trailer/Sledge Optional

Categories: