One 40′ ′ Requirement – – containerised Burner, and also comprehend you can aid us with […]
With years worth of experience in this field, our clinical array of incinerators are made to […]
Medical Waste Incinerator, 50 to 60 Kg/hrSupport Health Sector Support ProjectPoint of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals1. General DescriptionSupply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment. The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006). The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual. The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour. It shall be constructed from mild or aluminized steel lined with refractory material.Main unit Application For incineration, general and pathologicalCapacity 50 C 60 kg/h burn rateType Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time Minimum 8 hours dailyOperating temperature From 850 0C to 1200 0C, Automatic controlledResidual Ash 5 to 10% 3.2 Primary ChamberConstruction Constructed from heavy duty mild or aluminized steel Orequal and approved equivalentInsulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction Fixed hearth type complete with gratings, concave bottomand charging door, lined with refractory materialCharging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock Automatic, Electric typeAsh removal door Provided, for removing resultant bottom ash leftovers from the Primary chamberGratings […]
Functional Abilities PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE […]
Product Description Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in […]
Energy-efficient Incinerators for Medical Waste Management: Innovations and Solutions by HICLOVER In today’s world, effective medical […]
Main unit Application For incineration, general and pathological Capacity 50 – 60 kg/h burn rate […]
Basic Info. Type:Cremation Application:Dog, Cat, Bird Export Markets:Global Additional Info. Trademark:CLOVER Product Description Nanjing Clover Medical […]
1 Basic Plant Design An approved plant must have four distinct sections that demonstrate three principles […]
Animal Incinerator: Advanced Solutions for Efficient Animal Waste Management Animal waste management is a critical component […]
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce. ※ Main Attribute:— — Double Burning Chamber— — Double Italy Burner–– Burning Price: 10-100kgs per […]
Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control
we are waste incinerator manufacturer in china, focus on medical waste, pet animal and other solid […]
HICLOVER – Medical Environmental Model YD-30 (Custom Edition) Picture Burning Rate average 30 kgs/hour Feed Capacity average […]
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Application Scope: 1. Hospital& clinic: Iatric Waste, […]